| EC - Range |
0 to 400 mS/cm (shows values up to 1000 mS/cm), actual conductivity 1000 mS/cm**; 0.001 to 9.999 µS/cm*; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (autoranging) |
| Resolution |
0.001 µS/cm*; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
| Accuracy |
±1% of reading (±0.01µS/cm or 1 digit, whichever is greater) |
| Calibration |
automatic up to five points with seven memorised standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
| TDS - Range |
0.00 to 99.99 mg/L (ppm); 100.0 to 999.9 mg/L (ppm); 1.000 to 9.999 g/L (ppt); 10.00 to 99.99 g/L (ppt); 100.0 to 400.0 g/L (ppt) (autoranging) |
| Resolution |
0.01 mg/L (ppm); 0.1 mg/L (ppm); 0.001 g/L (ppt); 0.01 g/L (ppt); 0.1 g/L (ppt) |
| Accuracy |
±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater) |
| Resistivity - Range |
1.0 to 99.9 ?. cm; 100 to 999 ?. cm; 1.00 to 9.99 K?. cm; 10.0 to 99.9 K?. cm; 100 to 999 K?. cm; 1.00 to 9.99 M?. cm; 10.0 to 100.0 M?. cm* (autoranging) |
| Resolution |
0.1 ?. Cm; 1 ?. Cm; 0.01 K?. cm; 0.1 K?. cm; 1 K?. cm; 0.01 M?. cm; 0.1 M?. cm* |
| Accuracy |
±1% of reading (±10 ? or 1 digit, whichever is greater) |
| Salinity - Range |
% NaCl: 0.0 to 400.0 %; practical salinity: 0.00 to 42.00 (PSU); seawater scale: 0.00 to 80.00 (ppt) |
| Resolution |
0.1 %; 0.01 |
| Accuracy |
±1% of reading |
| Calibration |
max. one point only in % range (with HI-7037 standard); use conductivity calibration for all other ranges |
| Temperature - Range |
-20.0 to 120.0 °C |
| Resolution |
0.1 °C |
| Accuracy |
±0.2°C (excluding probe error) |
| Calibration |
one or two points |
| Additional Specifications: |
|
| Cell Constant Setup |
0.010 to 10.000 |
| Temperature Compensation |
NoTC, linear (-20.0 to 120.0°C), non linear (0 to 36°C) ISO/DIS 7888 std |
| Reference Temperature |
15°C, 20°C and 25°C |
| Temperature Coefficient |
0.00 to 10.00 %/°C |
| TDS factor |
0.40 to 1.00 |
| Probe |
HI-763133 stainless steel, four-ring conductivity/TDS probe with internal temperature sensor and 1.5 m (4.9’) cable (included) |
| Logging |
log-on demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples) |
| Memorised Profiles |
up to 10 |
| Measurement Modes |
autorange, autoend, lock and fixed range |
| PC Connectivity |
opto-isolated sealed USB (with HI-92000 software and micro USB cable) |
| Battery Type/Life |
1.5V AA batteries (4)/approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
| Auto-off |
user selectable: 5, 10, 30, 60 min, disabled |
| Environment |
0 to 50°C; RH 100% IP67 |
| Dimensions/Weight |
185 x 95 x 35.2 mm/400g |